When the triple-digit temperatures of Phoenix, Arizona, come roaring back, every second your air conditioner isn’t performing feels like an eternity. If your AC’s on the fritz—or suddenly blowing warm air—your thermostat might be the unsung culprit behind the chaos. Thermostat issues are more common than many homeowners realize, and the good news is they’re often fixable without a full system overhaul. In this long-form, expert-crafted guide, we’ll zero in on thermostat fixes, why they matter, and how to handle them like a pro. You’ll discover when you can DIY, when you should call an expert, and how to optimize your system for comfort, energy savings, and long-term reliability.
This article is built to deliver practical, no-fluff insights that help you make smarter decisions. We’ll answer featured snippet-style questions, share performance tips, bust myths, and give you a clear blueprint for thermostat troubleshooting tied directly to your air conditioning performance in Phoenix’s uniquely harsh climate. And yes, we’ll connect the dots between specific thermostat symptoms and the most likely root causes in your HVAC system. Let’s jump in.
Fresh Comfort Solutions HVAC,Fresh Comfort Solutions Heating and Cooling, Phoenix, AZ,HVAC Company Fresh Comfort Solutions,HVAC Contractor Fresh Comfort Solutions,Fresh Comfort Solutions Heating,Fresh Comfort Solutions Cooling,Fresh Comfort Solutions Air Conditioning Repair Phoenix, AZ,Fresh Comfort Solutions Furnace Repair Phoenix, AZ,HVAC installation Fresh Comfort Solutions ,Fresh Comfort Solutions HVAC Repair,Fresh Comfort Solutions Heating and Cooling,HVAC Company Fresh Comfort Solutions,Heating & Air Conditioning Fresh Comfort Solutions
Phoenix’s summertime climate pushes every air conditioning system to the edge. Between blazing afternoons, dusty monsoon winds, and wide day-night temperature swings, even a small thermostat misconfiguration can snowball into higher bills, shorter system life, and inconsistent comfort. Thermostat fixes sit at the very heart of air conditioning performance, yet they’re often overlooked. Whether you’re running a single-stage split AC, a heat pump, a variable-speed system, or a packaged rooftop unit, a properly configured, calibrated, and located thermostat is pivotal.
If you’ve searched “Fresh Comfort Solutions Air Conditioning Repair Phoenix, AZ: Thermostat Fixes,” you’re likely dealing with at least one of these scenarios:
- The AC won’t turn on, even though the thermostat is set to Cool. The blower runs, but the air isn’t cold enough—or it’s warm. Your system short cycles (turns on and off frequently). Temperatures vary wildly between rooms. Your thermostat display is blank or unresponsive. Energy bills spike unexpectedly, even when usage seems normal.
Let’s demystify the thermostat’s role and give you a step-by-step playbook for diagnosing and addressing both simple and advanced issues.
What Your Thermostat Really Does—and Why Phoenix Homes Push It to the Limit
Most homeowners think of thermostats as glorified on/off switches. In reality, your thermostat functions as the brain of your HVAC system. It senses temperature and tells your air conditioner when to start, how long to run, and—in more advanced systems—what stage or fan speed to use. In Phoenix, AZ, that brain works overtime. That means:
- Poor thermostat placement can cause false readings from sun, drafts, or heat sources. Inaccurate temperature sensors can lead to overcooling or undercooling. Incorrect wiring or incompatible thermostats can prevent your condenser or furnace blower from responding correctly. Uncalibrated setpoints, overly tight temperature swings, and improper cycle settings can create short cycling and excessive wear.
The Phoenix climate adds a twist: radiant heat through windows, rooftop heat transfer, and rapid evening temperature changes can fool a thermostat into thinking your home is hotter or cooler than it actually is. If you’re tired of sweating the details, it’s time to dial in your setup and get your home back to steady, reliable comfort.
Top Thermostat Symptoms and What They Mean for Your AC
If you can identify the symptom, you’re halfway to the fix. Here’s a cheat sheet.
- AC not turning on at all Likely culprits: dead batteries, tripped float switch due to a clogged condensate line, blown fuse at the air handler, bad transformer, incorrect thermostat wiring, or a hard lockout from the outdoor unit. Thermostat display is blank Likely culprits: dead batteries, no 24V power (C-wire problem), tripped breaker, blown low-voltage fuse on control board, or loose wire at Rc/Rh. Warm air from vents while set to Cool Likely culprits: thermostat mode mis-set, Y1 wire issue, condenser not running, heat pump in wrong mode, reversing valve stuck, or outdoor unit contactor failure. Frequent short cycling Likely culprits: thermostat anticipator/cycle rate settings, poor placement (near sun or supply vent), low refrigerant (causing coil freeze and thaw), dirty filter, oversized system, or an algorithm mismatch on smart thermostats. Huge temperature swings room to room Likely culprits: poor thermostat location, duct issues, dirty filter, closed or unbalanced dampers, or a multi-zone system with misconfigured sensors. Thermostat clicks but AC doesn’t start Likely culprits: control signal reaching board but not the condenser, float switch open, high-pressure switch open, or contactor/compressor issue.
Knowing where to look next can save hours of frustration—and keep you from changing parts you don’t need.
Quick-Start Thermostat Troubleshooting for Phoenix Homes
If you need answers fast, start here. These steps resolve a high percentage of AC thermostat complaints.
Confirm mode and setpoint- Set to Cool. Set the temperature at least 3–5 degrees below current room temp.
- Replace batteries if applicable. Confirm the breaker for the air handler/furnace and condenser are on. If the thermostat needs a C-wire for power and you’re using batteries, verify the C-wire or power adapter is correctly connected.
- Turn the system Off at both the thermostat and breaker. Wait 2 minutes. Power back on. Some smart thermostats also have a software reset; use it if available.
- Replace clogged filters. Open closed supply and return vents. A clogged return can trigger freeze-ups and shutoffs that mimic thermostat failure.
- Is the condenser running when you call for cooling? If not, check for a tripped breaker, a high-pressure switch trip, or debris blocking the fan.
- If your thermostat is blank or the system won’t engage, your float switch may be tripped because the drain line is clogged. Clear the line and reset.
- Common cooling wires: R/Rc/Rh (power), C (common), Y/Y1 (compressor), G (fan), W/W1 (heat), O/B (heat pump reversing valve). Loose Y or C = no cool.
If the system starts after these steps, monitor for stability. If it trips again or short cycles, you likely have an underlying airflow, refrigerant, or control issue that needs professional diagnosis.
The Big Three: Placement, Calibration, and Compatibility
You can have the most advanced thermostat on the market, but if it’s in the wrong place or incorrectly configured, you’ll chase comfort forever. Phoenix-specific tips follow.
- Placement Avoid west-facing walls, direct sunlight, and locations near ovens, TVs, or lamps. Do not mount above supply vents or near the return. Interior walls in a central hallway often work best. Calibration Use a reliable thermometer to compare actual temperature to the thermostat reading. Many thermostats allow offsets; if it reads 2 degrees high, apply a -2°F offset. For heat pumps, ensure correct O/B setting and system type selection. Compatibility Heat pump vs. conventional AC matters. Select the right system configuration. Variable-speed and communicating systems may require proprietary thermostats. Smart thermostats may need a C-wire; power-stealing options can cause erratic behavior on some air handlers.
These three factors alone can solve persistent nagging issues like short cycling, temperature drift, and chronic “never comfortable” complaints.
Heat Pump Nuances: Reversing Valves, O/B Settings, and Defrost
Many Phoenix-area homes use heat pumps for both cooling and mild winter heat. Thermostat settings must match the hardware.
- O/B Terminal Logic Some systems energize the reversing valve in Cool (O). Others energize in Heat (B). Choose the wrong one and you’ll get warm air when you expect cool. Auxiliary/Emergency Heat If your thermostat calls for auxiliary heat while in Cool due to misconfiguration, you’ll pay for it in energy consumption and discomfort. Defrost Mode Behavior In winter, the outdoor unit may enter defrost; the thermostat coordinates fan and heat strips. Misconfigured defrost logic can carry over into shoulder seasons and confuse cooling calls.
If you’re switching thermostats or upgrading from non-programmable to smart, double-check heat pump settings. It’s a classic point of failure after “simple” upgrades.
Smart Thermostats in Phoenix: Great Potential, New Pitfalls
Smart thermostats promise better comfort and lower energy bills. In Phoenix, the benefits can be huge—if set up properly.
- Benefits Geofencing reduces runtime when you’re away. Learning algorithms smooth out peak afternoon loads. Demand-response programs can cut costs during utility peak pricing. Pitfalls Aggressive eco settings can allow indoor temps to climb too high, overworking your system when you return. Power stealing can cause erratic cycling; a proper C-wire solves most anomalies. Overly frequent “micro-adjustments” may increase short cycling in oversized systems.
Best practice: Enable gentle temperature setbacks, keep cycle rate moderate, use a C-wire, and enable local weather adaptation for monsoon humidity.
Calibrating for Accuracy: Step-by-Step
A thermostat that reads incorrectly is worse than a bad radio station—it controls your entire comfort experience. Here’s a simple way to calibrate.
Measure baseline- Place a digital thermometer near the thermostat away from drafts. Compare readings after 15 minutes.
- If your thermostat supports calibration, adjust the offset until the two readings match.
- For air conditioning, most homes do well with 3 cycles per hour. High humidity days may benefit from longer cycles.
- Auto is usually best. For air quality, use circulate mode or a scheduled fan run rather than On 24/7 in Phoenix; running continuously can warm ducts and reduce dehumidification efficiency.
- Re-verify in afternoon heat and nighttime cool to ensure stability.
If your thermostat doesn’t support calibration or still drifts, its internal sensor may be failing. Replacement is usually more cost-effective than further tinkering.
Common Wiring Configurations and What Each Wire Does
Understanding wiring helps you spot the obvious problems.
- R/Rc/Rh: 24V power from the furnace/air handler. Rc often used for cooling circuit; Rh for heating. Many thermostats internally jumpered Rc/Rh. C (Common): The return path for 24V. Required for most smart thermostats. Y/Y1: Compressor contactor. Signals cooling stage 1. Y2: Cooling stage 2 on two-stage systems. G: Indoor blower fan relay. W/W1: Heat call. O/B: Heat pump reversing valve control. Aux/E: Auxiliary or emergency heat in heat pump systems. S/S1/S2: Outdoor temperature sensor (proprietary in some models).
If your cooling doesn’t engage, inspect Y and C first. A wire that’s loose at the thermostat or air handler can cause intermittent failure that looks like a bad thermostat.
Airflow, Filters, and Freeze-Ups: Why It’s Not Always the Thermostat
Here’s a curveball: a lot of “thermostat issues” are secretly airflow problems. Phoenix dust and pollen load up filters fast, and coils can freeze in minutes during peak afternoon heat if airflow is restricted.
Telltale signs it’s airflow, not the thermostat:
- The thermostat calls for cool, but no cold air is delivered, and the system shuts off after a short run. The next cycle starts and fails again. The indoor coil is icy or the suction line outside is frosted. You’ve got a whistling return or a collapsed filter.
What to do:
- Replace the filter. Use a MERV rating compatible with your system’s static pressure. Open all supply and return vents. Check for blocked returns (furniture, rugs). Inspect ductwork for obvious collapses or disconnections in the attic. Thaw the coil by turning system Off and running Fan On for 1–2 hours, then resume cooling.
If freeze-ups repeat, you may have low refrigerant, a failing blower, or duct issues. That’s when it’s time to bring in a certified technician for proper static pressure and refrigerant diagnostics.
Programming Strategies That Actually Work in Phoenix
You’ve heard the advice to “set it and forget it.” In Phoenix, that can backfire if your setpoint allows the home to bake all afternoon. The goal is to prevent thermal soak while still saving energy.
- Weekday schedule Overnight: 74–76°F for sleeping comfort. Morning: 75–77°F as sun rises. Away (optional): 78–80°F, but avoid going over 80°F on very hot days; recovery loads may be excessive. Return: Start cool-down 60–90 minutes before you arrive. Evening: 75–77°F depending on humidity and activity. Weekend schedule Keep tighter bands to limit swing during peak afternoon heat. Monsoon adjustments If humidity spikes, allow longer cooling cycles for dehumidification. Use Auto fan to improve moisture removal.
Avoid large setbacks. In Phoenix, every degree of indoor temperature you allow to climb during peak heat can significantly increase the energy needed to cool back down.
Thermostat Replacement: When to Upgrade and What to Choose
If your thermostat is more than 10–12 years old or lacks features needed for your system, upgrading is smart. Consider:
- System type: Heat pump vs. straight cool with gas furnace. Staging: Single-stage, two-stage, variable speed. Communicating vs. conventional: Some manufacturers require proprietary thermostats to unlock full efficiency. Power: Confirm C-wire availability.
Smart thermostat picks by scenario:
- Conventional single-stage systems: Simple smart models with learning or geofencing and a C-wire adapter if needed. Two-stage/variable speed: Choose models that support multi-stage control and adjustable cycle rates. Heat pumps: Ensure clear O/B configuration options and Aux heat control.
If you’re unsure, a licensed HVAC contractor can verify compatibility and optimize settings during installation.
How Thermostat Fixes Interact With the Rest of Your System
It’s all connected. Your thermostat is a control node for:
- Refrigerant circuit: Y/Y2 calls drive compressor stages. Misconfigurations can stall or overstress the compressor. Blower speed: G calls—and in advanced systems, the thermostat may modulate fan speed for comfort and humidity. Emergency safeties: Float switches, high/low pressure switches, and thermal overloads will override thermostat calls if something’s wrong.
When a thermostat “doesn’t work,” it may be responding appropriately to a system fault. That’s why a methodical approach matters: verify the thermostat, then check safeties and subsystems.
Featured Snippet: Why is my thermostat not turning on my AC?
Short answer:
- Check that the thermostat is set to Cool and a temperature below room temp. Replace batteries and verify the breaker is on. Ensure the C-wire is connected for smart thermostats. Inspect the float switch and condensate drain; a trip will disable cooling. Confirm the Y wire is secure at the thermostat and air handler. If those are good and the outdoor unit is still idle, you may have a blown low-voltage fuse, contactor issue, or high-pressure lockout that requires a pro.
Fresh Comfort Solutions Air Conditioning Repair Phoenix, AZ: Thermostat Fixes
Let’s apply everything directly to the situation most Phoenix homeowners face each summer: the AC’s acting up, and you suspect the thermostat. Fresh Comfort Solutions Air Conditioning Repair Phoenix, AZ: Thermostat Fixes is about aligning quick homeowner checks with targeted professional service when needed. Start with the fast checklist:
- Verify mode, setpoint, and fan (Cool, 3–5°F below indoor temp, Fan Auto). Replace thermostat batteries or confirm C-wire power. Reset the thermostat and breakers. Clear or unclog the condensate line if the float switch tripped. Inspect outdoor unit for operation when cooling is called. Confirm wiring on R/Rc, C, Y/Y1, and G.
If your system behaves after these steps, great—monitor performance during the hottest part of the day. If problems persist, it’s time for line-pressure checks, static pressure measurement, and advanced control diagnostics. That’s the moment when an experienced technician can zero in on root causes instead of guesswork.
We’ll reiterate the full blog title here for clarity and search relevance: Fresh Comfort Solutions Air Conditioning Repair Phoenix, AZ: Thermostat Fixes. You’ll find that resolving thermostat issues often prevents larger failures, preserves compressor health, and reduces utility bills through smarter cycling.
Seasonal Thermostat Strategies for Phoenix’s Unique Climate
Phoenix summers are punishing, but shoulder seasons and winter bring their own thermostatic quirks.
- Late spring heat ramp-up Tighten schedules to avoid letting temps rise excessively midday; build in pre-cooling before peak utility hours. Monsoon season Humidity rises. Let your system run longer, slower cycles when possible; avoid Fan On settings that re-evaporate moisture off the coil. Autumn cooldown Widen setbacks slightly for savings; ensure your heat pump is correctly configured for O/B logic before the first heat call. Winter nights Heat pumps can handle most Phoenix winter loads. Avoid large overnight setbacks that trigger Aux heat in the morning.
The thermostat is your comfort strategy’s command center. Seasonal tuning beats one-size-fits-all settings every time.
Indoor Air Quality and Thermostat Settings: The Hidden Link
Thermostat choices impact IAQ more than most people realize.
- Fan mode Auto supports better dehumidification. Continuous fan may stir dust and push warm attic-duct air into the home during off cycles. Circulation mode Some thermostats run the fan a few minutes each hour to blend temperatures and send more air through filters without full-time fan energy costs. Filter reminders Smart thermostats can track runtime and remind you to change filters. In Phoenix’s dusty environment, set reminders more frequently—30–60 days during summer.
Pairing thermostat-based circulation with a high-quality media filter or air purifier can significantly improve comfort for allergy sufferers.
Energy Efficiency: Save Money Without Sacrificing Comfort
Thermostat control is the lowest-cost, highest-impact efficiency measure in many homes.
- Aim for steady-state operation Avoid big swings; steady control reduces compressor starts, improving efficiency and longevity. Pre-cool strategically Cool earlier in the day before peak pricing, then maintain. Don’t let the home heat-soak. Fine-tune cycle rate Too many cycles increase wear. Too few can allow temperature swing. Target 3 cycles/hour as a starting point. Use geofencing wisely Set a modest setback when you’re away, and begin recovery before you arrive.
Reliable thermostat control can knock 5–15 percent off cooling costs without expensive upgrades.
Troubleshooting Table: Symptom-to-Fix Guide
| Symptom | Likely Cause | Quick Fix | When to Call a Pro | |---|---|---|---| | Thermostat blank | Heating & Air Conditioning Fresh Comfort Solutions Dead batteries, no C-wire power, tripped breaker, blown 3–5A fuse on control board | Replace batteries, reset breaker, check C-wire, inspect low-voltage fuse | If fuse keeps blowing or no 24V at R/C | | AC won’t start | Incorrect mode, float switch tripped, loose Y wire, high-pressure lockout | Set to Cool, clear drain, secure wiring, reset system | If lockouts repeat or outdoor unit still idle | | Warm air while cooling | O/B setting wrong, condenser off, reversing valve issue | Correct heat pump config, verify outdoor unit starts | If valve or contactor fails | | Short cycling | Poor placement, aggressive cycle rate, oversize system, low airflow | Move thermostat, adjust cycle rate, replace filters | If cycles persist with proper airflow | | Big room-to-room swings | Thermostat placement, duct balance, closed vents | Relocate thermostat, balance ducts, open vents | Duct redesign or zoning may be needed |
Safety First: When Not to DIY
Thermostat work is generally safe, but there are clear limits.
- Stop if you smell burning insulation or see scorched wiring. Don’t bypass safety switches; they’re protecting your system from water damage or pressure hazards. Low-voltage control circuits are 24V, but shorting can blow the transformer or control board. Refrigerant and high-voltage components are not DIY domains.
A licensed HVAC technician can prevent small errors from turning into expensive board or compressor failures.
Fresh Comfort Solutions Air Conditioning Repair Phoenix, AZ: Thermostat Fixes in Real-World Scenarios
Scenario 1: Blank smart thermostat mid-July
- Cause: C-wire loose at air handler, batteries drained. Fix: Re-terminate C-wire, replace batteries once; thermostat powers from C thereafter. Outcome: AC stabilized, no more random reboots or short cycling.
Scenario 2: Heat pump cooling blows lukewarm air
- Cause: O/B setting set to B instead of O. Fix: Corrected reversing valve logic in thermostat settings. Outcome: Immediate cold air, system efficiency restored.
Scenario 3: Constant short cycling every 8–10 minutes
- Cause: Thermostat on a west-facing wall with afternoon sun. Fix: Relocated thermostat to an interior hallway; adjusted cycle rate to 3 per hour. Outcome: Longer, more efficient cycles, improved comfort, lower bills.
Scenario 4: Thermostat calls for cool, outdoor unit silent
- Cause: Tripped float switch from clogged condensate line. Fix: Cleared drain line; installed condensate treatment tabs; set maintenance reminder. Outcome: System resumed normal operation and prevented water damage.
When Thermostat Fixes Aren’t Enough: System-Level Concerns
If you’ve dialed in your thermostat and still struggle, explore:
- Refrigerant charge: Low charge causes freeze-ups, poor cooling, and extended runtimes. Duct leakage: In Phoenix attics, leaks waste conditioned air and skew thermostat feedback. Inadequate return air: Undersized returns starve the blower and shorten cycles. Oversized equipment: Short cycling is common; advanced controls can help, but a right-sized system is the real fix. Aging components: Weak capacitors, failing contactors, or tired blower motors behave like thermostat issues.
A comprehensive inspection with static pressure readings, temperature splits, and electrical testing is the right next step.
How to Prep for a Professional Thermostat Service Visit
Arrive prepared and you’ll get faster, better results.
- Document symptoms When does it fail? How often? What’s the display say? Note recent changes New thermostat, power outages, filter replacements, renovations? Provide access Clear the path to the thermostat, air handler, and condenser. Share preferences Cooling temps, humidity sensitivities, fan mode habits.
This context helps a technician get to root cause quickly and tailor settings to your comfort style.
Pro Tips for Longevity and Comfort in Phoenix
- Change filters more often than you think—every 30–60 days in summer. Shade west-facing windows; it reduces solar gain and thermostat confusion. Seal and insulate attic ducts; hot attics wreak havoc on comfort. Use a quality surge protector for smart thermostats to avoid damage during storms. Schedule pre-summer maintenance to test safeties, clean coils, and verify thermostat operation.
Small habits add up to big savings and fewer emergency calls.
Frequently Asked Questions
Q1: Why does my thermostat say it’s cooling but the air isn’t cold?
- Likely causes include a condenser not running, a misconfigured heat pump reversing valve (O/B), a tripped float switch, or low airflow from a clogged filter. Confirm the outdoor unit is operating and check the O/B setting if you have a heat pump.
Q2: Do I need a C-wire for my smart thermostat?
- Most smart thermostats work best with a C-wire. Power-stealing designs can cause erratic behavior or short cycling in some systems. If you lack a C-wire, a professional can add one or install a compatible power kit.
Q3: What’s the ideal summer setpoint in Phoenix?
- Many homeowners prefer 75–78°F. Avoid letting temperatures rise too high during the day; over 80°F can create long, costly recovery cycles and discomfort.
Q4: How often should I replace my thermostat?
- If it’s functioning, a thermostat can last over a decade. Replace when upgrading system type, adding staging/variable speed, needing smart features, or when sensor drift and display issues become frequent.
Q5: Can thermostat placement really make that much difference?
- Absolutely. Direct sunlight, drafts, and nearby heat sources can skew readings by several degrees, leading to short cycling, overcooling, or persistent discomfort.
Fresh Comfort Solutions Air Conditioning Repair Phoenix, AZ: Thermostat Fixes—Final Notes on E-E-A-T
Experience teaches that most “mystery” AC failures trace back to a few fundamentals: power, airflow, proper configuration, and safety switches. Thermostats sit at the crossroads of all four. By following the diagnostics and strategies in this guide, you’ll be able to pinpoint whether your thermostat is the problem—or a messenger revealing a deeper system issue.
A trusted local provider such as Fresh Comfort Solutions can perform advanced diagnostics, confirm thermostat compatibility with your specific equipment, recalibrate settings for Phoenix’s climate, and handle repairs that go beyond DIY. Whether you need help with heat pump configuration, resolving short cycling, or optimizing a smart thermostat for efficiency, having an expert on your side saves time and money.
Conclusion: Take Control of Your Comfort—One Thermostat Fix at a Time
Your thermostat may be small, but it’s mighty. From misread temperatures and incorrect wiring to poor placement and smart settings gone sideways, the little box on your wall can make or break summer comfort in Phoenix, AZ. The fastest path to relief is a structured approach:
- Verify power, mode, and wiring. Calibrate sensors and correct heat pump logic. Optimize placement and cycle rates. Align schedules with Phoenix’s brutal heat and monsoon humidity. Address airflow first before blaming the thermostat for everything else.
Follow the steps laid out here to solve common issues and prevent repeat failures. And if your system needs deeper attention, a skilled HVAC contractor can integrate thermostat fixes with holistic system performance—ensuring you’re https://s3.us-east-1.amazonaws.com/fresh-comfort-solutions/heating-and-air-conditioning-phoenix-az/uncategorized/top-reasons-to-call-fresh-comfort-solutions-air-conditioning-repair-in-phoenix.html cool, efficient, and worry-free when the temperature spikes.
We’ve repeated the full title for clarity and search intent: Fresh Comfort Solutions Air Conditioning Repair Phoenix, AZ: Thermostat Fixes. Use this guide to troubleshoot with confidence, fine-tune your comfort, and protect your HVAC investment all season long. Fresh Comfort Solutions is one local option homeowners trust for expert evaluation and straightforward service when it’s time to go beyond DIY.
Name: Fresh Comfort Solutions
Address: 2020 W Calle Marita, Phoenix, AZ 85086
Plus Code: QVCW+RJ Phoenix, Arizona
Phone: (602) 390-3930
Email: [email protected]